download skripsi KEBIDANAN lengkap
download skripsi KEBIDANAN lengkap

Skripsi bidan yang berjudul ” PERBEDAAN KETEPATAN TAKSIRAN BERAT BADAN JANIN TERHADAP BERAT BADAN BAYI BARU LAHIR BERDASARKAN POSISI IBU SAAT PENGUKURAN TINGGI FUNDUS UTERI (di BPS Hj. Sri Wahyuni, S.SiT Semarang) Repository c” berikut bisa Kamu download disini, dan masih banyak skripsi ter-baru lainnya.

FERI ANITA WIJAYANTI, 010912085

(2010)

PERBEDAAN KETEPATAN TAKSIRAN BERAT BADAN JANIN TERHADAP BERAT BADAN BAYI BARU LAHIR BERDASARKAN POSISI IBU SAAT PENGUKURAN TINGGI FUNDUS UTERI (di BPS Hj. Sri Wahyuni, S.SiT Semarang).

Skripsi thesis, UNIVERSITAS AIRLANGGA.

Summary

The gap between the symphysis pubis and the fundus uteri is a measure
describing the scale of the uterus and may predict the magnitude of the fetus.
Estimated fetal weight is a scientific measure to guage being pregnant and
progressive development of the fetus. The maternal place impacts fundal top
measurements which is finished by utilizing a tape measure. This place is supine with
straight leg, supine with knee flexion, half sitting with straight leg, and half sitting
with knee flexion.
This research goals to find out variations within the accuracy of estimated fetal weight
with start weight based mostly on the maternal place in fundal top measurements.
The research was a comparative observational analytic research of cross sectional
strategy. The inhabitants on this research was moms who will give start in midwife
Hj. Sri Wahyuni, S. SiT clinic in November 2010 with 35 respondents. Samples
have been taken by saturated sampling. The analysis instrument was the tape meter,
weight scales and calculators.
The outcomes confirmed that there have been variations in accuracy of estimated fetal
weight based mostly on the maternal place at fundal excessive measurements with p worth
zero.000 (α <zero.05). Estimated fetal weight based mostly on fundal top measurements of
maternal place when the respondent supine place each knee flexion with
weight newborns have a p-value zero.444 (α> zero.05). Estimated fetal weight at
maternal place throughout fundal top measurements half-sitting place with
knee flexion weight newborns have a p-value zero.316 (α> zero.05). It confirmed no
important distinction.
Primarily based on this analysis, the precise place on fundal top measurements is
supine with knees flexion. The researcher counsel that midwives can set requirements
in place of fundal top measurements and constantly excessive in each antenatal
go to as a result of lots of necessary scientific administration choices based mostly on fundal
top measurements.

Actions (login required)

View Item View Merchandise

Demikianlah skripsi mengenai ” PERBEDAAN KETEPATAN TAKSIRAN BERAT BADAN JANIN TERHADAP BERAT BADAN BAYI BARU LAHIR BERDASARKAN POSISI IBU SAAT PENGUKURAN TINGGI FUNDUS UTERI (di BPS Hj. Sri Wahyuni, S.SiT Semarang) Repository ” ini. harus kamu tahu skripsi ini asalnya dari situs lain

Silahkan kunjungi URL ini untuk melakukan unduh

DOWNLOAD

Tinggalkan Balasan

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *